Industrial remote control common fault analysis
Release Time2024-01-30      Number of clicks:136

Q: What if there is no response from the launcher?

A: The reason may be that there is no power supply. Try the following methods: Check whether the battery is sufficient. If it is insufficient, replace the battery or charge the battery. Check battery or remote control contacts for damage or corrosion.


Q: What if the red light of the transmitter blinks once a second, accompanied by a beep?

A: The reason may be that the battery is low. Try the following methods: Check whether the battery is sufficient. If it is insufficient, replace the battery or charge the battery. Check battery or remote control contacts for damage or corrosion.


Q: What if the transmitter light blinks red and green alternately?

A: The reason may be that the intelligent chip ILOG is not recognized. Try the following methods: Check that the ILOG is installed and that the number on the ILOG chip is the same as the system number.


Q: What if the transmitter start indicator flashes red and green quickly (rocker system)?

A: The possible cause is that the protection mechanism is not reset. Try the following: Check that the switch in the safety protection mechanism is reset.


Q: What if the transmitter indicator is normal, but there is no output action?

A: The cause may be that the receiver is not powered on, the transmitter and receiver are not connected, and the "start" command is not activated. Please try the following methods: Check the receiver cable, check the receiver indicator status.


Q: What if some actions have no output?

A: The reason may be that the receiver is faulty and the cable between the receiver and the controlled device is disconnected. Try the following: Check that all cable interfaces are tight.


Q: What if the stateless indicator lights up after the receiver is connected to the machine?

A: The reason may be that there is no power supply. Please try the following methods: check whether the machine has power, check whether the receiver and the machine are connected properly, check whether the internal safety of the receiver is damaged.


Q: What if the transmitter turns on normally, the receiver has been powered on, and the status is normal, but it cannot be connected?

A: The reason may be that the receiver antenna is damaged. Try the following: Replace the antenna.